B-Flap I PRO - Explosion isolation flap
The innovated explosion isolation flap B-FLAP I PRO is certified according to EN 16447 and EN 15089. B-FLAP I PRO was tested by an accredited laboratory with emphasis on real-world conditions in the various production processes.
With the innovation, we bring extended installation options for the explosion isolation flap valve. According to current standards and certifications, the explosion isolation flap can be installed in horizontal and vertical pipeline. It can be used in aspiration systems with pull or push flow. B-FLAP I PRO can also be installed on pipelines containing obstacles or elbows between the protected equipment and the place of installation of the explosion isolation flap. A novelty is also higher pressure resistance (pmax) of the isolation flap valve and increased maximum reduced pressure (pred,max) of the protected vessel, from which a potential explosion spreads. According to the latest tests and certifications, the minimum installation distance has been shortened, and the maximum installation distance from the protected equipment has been extended.
The B-Flap I PRO explosion isolation flap can stop the propagation of an explosion caused by processed organic, melting, coarse, and metal dusts up to explosion class St 3 and dusts with very low values of minimum initiation energy (MIE) and temperature (MIT). This new design of the B-FLAP I PRO explosion isolation flap makes it easier to handle during the installation and operational maintenance.
WHERE IS THE RISK?
In piping systems, during material conveying between individual parts of the production technology, initiation source (e.g. hot surface, friction, a spark from equipment failure, etc.) can be easily formed, which in combination with the flowing air and the transported material creates an explosive mixture. The pressure wave and the flame bursting through the piping system can explode and thus destroy the connected technologies or endanger personnel within a close range.

ADVANTAGES
PREVENTION OF EXPLOSION PROGATION BETWEEN
ENHANCED TECHNICAL PARAMETERS OF B-FLAP I
The explosion isolation flap valve provides customers with effective measures to prevent explosion propagation between interconnected technologies. By isolating explosions within the entire pipeline of suction systems, this flap valve not only safeguards against explosion transmission at inlet points like filters or cyclones but also effectively contains explosions within outlet piping from filtration systems (known as the “clean side” of the filter). Additionally, B-FLAP I offers versatile installation options, including placement on suction lines to mills, at material inlet points for dryers, and similar equipment.
B-FLAP I is a mechanical device engineered to halt the transfer of flame and pressure between technologies during explosions. During regular operations, the explosion isolation flap valve remains open via the RPD mechanism, minimizing pressure losses in the piping system. In the event of an explosion, the protected pipe is swiftly closed and secured, bolstering overall safety alongside other protective features. Frequently, B-FLAP I is employed alongside explosion venting devices such as VMP or FLEX, and it is compatible with pipes ranging from DN 100 to DN 800 in diameter.
For pneumatic conveying systems, vertical piping with diameters under DN 100, or setups designed for maximum explosion pressure or shorter installation distances, alternatives like GatEx or HRD barriers may be more suitable.
FOOD INDUSTRY - MALTHOUSE
Malthouses are an integral part of the food industry. These following references from installations will show you all risk areas, including the selection of the most suitable explosion protection.

TECHNICAL PARAMETERS
Type | ØA (mm) |
ØB (mm) |
ØC (mm) |
L (mm) |
N (mm) |
P (mm) |
Weight (kg) |
DN 100 | 152 | 132 | 100 | 280 | 287 | 244 | 9 |
DN 125 | 177 | 157 | 125 | 305 | 308 | 269 | 11 |
DN 150 | 202 | 182 | 150 | 330 | 337 | 294 | 13 |
DN 200 | 253 | 233 | 200 | 390 | 387 | 344 | 18 |
DN 250 | 303 | 283 | 250 | 510 | 502 | 417 | 41 |
DN 280 | 343 | 317 | 280 | 560 | 537 | 447 | 48 |
DN 300 | 363 | 337 | 300 | 580 | 552 | 467 | 51 |
DN 315 | 378 | 352 | 315 | 600 | 567 | 482 | 54 |
DN 355 | 418 | 392 | 355 | 630 | 607 | 522 | 62 |
DN 400 | 464 | 438 | 400 | 695 | 652 | 568 | 73 |
DN 450 | 514 | 488 | 450 | 750 | 702 | 619 | 88 |
DN 500 | 564 | 538 | 500 | 800 | 752 | 669 | 101 |
DN 560 | 664 | 629 | 560 | 930 | 838 | 745 | 157 |
DN 630 | 734 | 698 | 630 | 1005 | 908 | 815 | 180 |
DN 710 | 814 | 775 | 710 | 1156 | 1102 | 967 | 305 |
DN 800 | 904 | 861 | 800 | 1246 | 1193 | 1057 | 351 |

VISUALIZATION 1
- Type of protection: Explosion venting device VENT PRO
- Installation of B-FLAP I PRO: Inlet and outlet pipe
- Position of B-FLAP I PRO: Horizontal

VISUALIZATION 2
- Type of protection: Flameless explosion venting device Flex
- Installation of B-FLAP I PRO: Inlet pipe to the filter
- Position of B-FLAP I PRO: Horizontal

VISUALIZATION 3
- Type of protection: Explosion venting device VENT PRO
- Installation of B-FLAP I PRO: Inlet and outlet pipe
- Position of B-FLAP I PRO: Horizontal

VISUALIZATION 4
- Type of protection: Flameless explosion venting device
- Installation of B-FLAP I PRO: Inlet and outlet pipe
- Position of B-FLAP I PRO: Horizontal

VISUALIZATION 5
- Type of protection: Explosion venting device VENT PRO
- Installation of B-FLAP I PRO: Inlet and outlet pipe
- Position of B-FLAP I PRO: Horizontal

VISUALIZATION 6
- Type of protection: Flameless explosion venting device
- Flex Installation of B-FLAP I PRO: Inlet and outlet pipe
- Position of B-FLAP I PRO: Horizontal

VISUALIZATION 7
- Type of protection: Explosion venting device VENT PRO
- Installation of B-FLAP I PRO: Inlet and outlet pipe
- Position of B-FLAP I PRO: Vertical

VISUALIZATION 8
- Type of protection: Flameless explosion venting device Flex
- Installation of B-FLAP I PRO: Inlet and outlet pipe
- Position of B-FLAP I PRO: Vertical

VISUALIZATION 9
- Type of protection: Explosion venting device VENT PRO
- Installation of B-FLAP I PRO: Inlet and outlet pipe
- Position of B-FLAP I PRO: Vertical

VISUALIZATION 10
- Type of protection: Flameless explosion venting device Flex
- Installation of B-FLAP I PRO: Inlet and outlet pipe
- Position of B-FLAP I PRO: Vertical